Ventio

Feasibility of High-Resolution Enhanced Susceptibility Mapping from Mono-Echo 3D EPI Using a Mask-Free Reconstruction Framework

Stéphane ROCHE1*, Samira MCHINDA1*, Aurélien MASSIRE2, Ludovic de ROCHEFORT1, Blanche BAPST3,4,5

  1. Ventio SAS, Marseille, France
  2. Siemens Healthcare SAS, Courbevoie, 92400, France
  3. Department of Neuroradiology, AP-HP, Henri Mondor University Hospital, Créteil, 94000, France
  4. EA 4391, Université Paris Est Créteil, Créteil, 94000, France
  5. CEA, NeuroSpin, CNRS, Université Paris-Saclay, Gif-sur-Yvette, 91191, France

42nd annual meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB), Sep 2026, Girona, France. ⟨hal-05783147⟩

Introduction: Quantitative susceptibility mapping (QSM)1 is a powerful MRI tool for probing tissue magnetic susceptibility, with increasing clinical relevance. Current ISMRM consensus recommendations2 emphasise multi-echo gradient echo (GRE) acquisitions. However, these approaches remain limited by relatively long acquisition times and sensitivity to motion, restricting their use in time-constrained or clinically challenging settings. Mono-Echo 3D EPI acquisitions are also sensitive to susceptibility, such that they can be used for QSM. Recently, deep-learning reconstruction3 strategies were used to enhance resolution in clinical settings reaching sub-millimeter voxel sizes in a few minutes. In this work, we show the feasibility of a new mask-free processing framework that enables the reconstruction of quantitative susceptibility maps from such mono-echo data, thereby providing high-resolution enhanced susceptibility mapping in a few minutes at clinical field strength.

Methods: MR examination was performed on a Multiple Sclerosis (MS) patient on a clinical 3T MR system (Magnetom Prisma, Siemens Healthineers, Forchheim, Germany) equipped with a 64-channel head/neck coil. The MR sequence employed was a prototypal segmented 3D-EPI with Deep-Learning reconstruction, super-resolution and advanced phase processing. Acquisition time was 3min02s with a reconstructed 0.5×0.5×0.65mm3 spatial resolution, axial orientation, water excitation and a single echo time of 27 ms. 3D FLAIR images were also acquired providing lesion references. 3D-EPI high resolution data were processed with a dedicated and robust strategy to provide whole-head Enhanced Susceptibility Mapping (ESM). Phase unwrapping and background field removal were performed using a Laplacian-based approach4. Magnetic susceptibility map was then estimated using a constrained optimisation (maximum likelihood) formulation with zeroth- and second-order derivative priors.

Results: The method demonstrates the feasibility of mask-free enhanced susceptibility mapping from mono-echo high-resolution 3D-EPI deep-learning reconstruction without anatomical masking (Figure 1). Qualitative analysis confirms detailed visualization of brain tissues, notably deep gray nuclei. Minimum intensity projection led to enhanced visualization of veinous network. MS lesions appeared to have different ESM features such as paramagnetic rim, central vein sign, or iso-intensity (Figure 2). Calcifications could also be detected in choroid plexuses and in putamen.

Conclusion: The proposed approach enables whole-brain high resolution enhanced susceptibility mapping from mono-echo 3D EPI deep learning magnitude and phase reconstruction, supporting effective discrimination between para- and diamagnetic sources without the need for anatomical masking, with a high potential for robust tissue characterization applied to multiple sclerosis.

Data and Code Availability Statement:

The authors thank Josef Pfeuffer for providing the prototypal 3D-EPI MR sequence with Deep-Learning reconstruction and advanced raw phase processing under a Research Software Package.

ESM code implements a proprietary methodology that is currently the subject of a pending patent application resulting from a project funded by the “Sud” region and by the French government as part of the France 2030 investments for the future plan.

References:

1.           de Rochefort L, Liu T, Kressler B, et al. Quantitative susceptibility map reconstruction from MR phase data using bayesian regularization: Validation and application to brain imaging. Magn Reson Med. 2010;63(1):194-206. doi:10.1002/mrm.22187

2.           QSM Consensus Organization Committee, Bilgic B, Costagli M, et al. Recommended implementation of quantitative susceptibility mapping for clinical research in the brain: A consensus of the ISMRM electro-magnetic tissue properties study group. Magn Reson Med. 2024;91(5):1834-1862. doi:10.1002/mrm.30006

3.           Gkotsoulias DG, Weigel M, Cagol A, et al. A pilot study assessing the clinical utility of deep learning-reconstructed 3D-echo-planar-imaging-based quantitative susceptibility mapping in multiple sclerosis. Front Neurosci. 2025;19:1544376. doi:10.3389/fnins.2025.1544376

4.           de Rochefort L. Quantitative Susceptibility Mapping in Vivo in the Rat Brain. In: 2010.

Figure 1: Exemplary slice of a FLAIR image reference (a), reconstructed filtered phase (b) and magnitude (c) high resolution 3D EPI with deep learning reconstruction at 0.5x05x0.65 mm acquired in 3 min at 3T on a MS patient. Enhanced Susceptibility Map (ESM, e), Maximum (d) and minimum (f) intensity projection over 15 slices generated from the single echo 3D EPI. The chosen convention is to represent diamagnetic in white and paramagnetic in black. ESM highlights anatomical structures, MIP emphasizes calcifications and mip delineates the paramagnetic venous network and structures.

Figure 2: Zoom on various lesions. L.1: juxta-cortical FLAIR lesion with a possible paramagnetic rim (phase/ESM/mip); L.2: periventricular FLAIR lesion with typical central vein sign (MAG and ESM); L.3: a WM FLAIR lesion with barely detectable effects in phase and ESM; L.4 a small WM FLAIR lesion with a visible presence of a possible vein in the vicinity (ESM); C.1 calcification in the choroid plexuses (MIP); C.2 possible calcifications in the putamen (hyposignal on MAG, hypersignal on ESM).